Diabetes Care

Self-monitoring blood glucose provides useful information for
diabetes management.

Diabetes Care

Self-monitoring blood glucose provides useful information for
diabetes management.

FORA® 6 Series

Multi-functional Monitoring System — Measures six parameters

FORA® Diamond Series

Blood Glucose Monitoring System (GDH)

FORA® COMFORT Series

Blood Glucose Monitoring System

FORA® COMFORT Series

Blood Glucose Monitoring System (GDH-FAD)

PROFESSIONAL Series

Blood Glucose and ß-ketone Monitoring System

Meters

NameFORA 6 PlusFORA 6 ConnectFORA 6 GTel
Model NumberGD81GD82GD84
Test StripsBlood Glucose, 3-in-1
(BG/HCT/BG), β-Ketone, Uric
Acid and Total Cholesterol
Blood Glucose, 3-in-1
(BG/HCT/BG), β-Ketone, Uric
Acid and Total Cholesterol
Blood Glucose, 3-in-1
(BG/HCT/BG), β-Ketone, Uric
Acid and Total Cholesterol
Universal ToneYesYesNo
Talking GuidanceNoNoYes
Button DesignNoNoYes
Two Way MessageNoNoYes
Encouraging ReminderNoNoYes
Service ButtonNoNoYes
Trends and GraphsNoNoYes
Memory Capacity1,000 memory sets1,000 memory sets1,000 memory sets
Strip EjectionYesYesYes
Strip Feed LightYesYesYes
Daily Alarm4 Alarms4 Alarms4 Alarms
Ketone WarningYes, if ≥ 240 mg/dLYes, if ≥ 240 mg/dLYes, if ≥ 240 mg/dL
Meal TagAutoQC mode; GEN / AC / PCAutoQC mode; GEN / AC / PCBefore Meal / After Meal / No Tag
7, 14, 21, 28, 60, 29 – Day AverageYesYesYes
DisplayLCD BacklightLCD BacklightColor Touch Screen
Data ConnectionUSB-Strip Port COM CableBluetooth 4.0SIM (3G/4G)
Power SourceAAA x 1AAA x 1Li-Polymer Battery

Test Strips

Strip TypeBlood Glucose (BG)BG/HCT/HBβ-ketone (KB)Uric Acid (UA)Total Cholesterol (TCH)
Enzyme TypeGDH-FADβ-Hydroxybutyrate DehydrogenaseUric Acid Catalyst
Cholesterol Esterase
Cholesterol Oxidase
Blood Sample Requirement0.5 μL0.8 μL1.0 μL3.0 μL
Reaction Time5 Seconds10 Seconds15 Seconds60 Seconds
Measurement Range
100 ~ 600mg/dLBG: 10 ~ 600 mg/dL
(0.55 ~ 33.3 mmol/L)HB: 0 ~ 23.8 g/dL
0.1 ~ 8.0 mmol/L3 ~ 20 mg/dL100 ~ 400 mg/dL
Hematocrit Range0 ~ 70%10 ~ 70%20 ~ 60%20 ~ 60%
Precision
SD < 5 mg/dL (0.278 mmol/L) if < 100
mg/dL (5.55 mmol/L);
CV < 5% if ≥ 100 mg/dL (5.55 mmol/L)
≤ 1 mmol/L, SD <0.1mM;
> 1 mmol/L, CV < 7.5%
CV < 7.5%CV < 7.5%
Accuracy± 15mg/dL if < 100 mg/dL; ± 15% if ≥ 100
mg/dL
Alternative Site Testing (AST)Fingertips, Palm, Upper Arm or ForearmNot ApplicableNot ApplicableNot Applicable
Applicable Sample TypeCapillary; VenousCapillary; VenousCapillary; VenousCapillary; Venous
Storage Condition2°C (36.6°F) ~ 30°C (86.0°F); RH < 90%2°C (36.6°F) ~ 30°C (86.0°F);
RH < 85%
2°C (36.6°F) ~ 30°C
(86.0°F); RH < 85%
2°C (36.6°F) ~ 30°C
(86.0°F); RH < 85%
Strip PackVial / Individual PackVial / Individual PackVial / Individual PackVial / Individual PackVial / Individual Pack
Shelf Life Time24M / 18M24M / 18M18M18M18M

To Know More, Get in Touch With Us